Circular LiPo Battery
- Item:: Round Lipo Battery GMB483533HV
- Brief:: Circular shape, 3.8V 550mAh.
Publish time:2020-01-16 16:51:05
Circular Lipo Battery 3.8V 550mAh
Publish time:2020-01-16 16:51:05
Circular Lipo Battery 3.8V 550mAh
1.2 Model: GMBT483533HV
No.
| Item
| Spec
| Note
| ||||||
1 | Nominal Capacity
| ≥550mAh@ 0.2C DischargeMin:530mAh | 0.2Crate,3.0V cut-off | ||||||
2 | Nominal Voltage | 3.8V | |||||||
3 | MAX Charge Voltage
| 4.35V | |||||||
4 | Discharge Cut-Off Voltage
| 3.0 V | |||||||
5 | Charge current
| Standard charge: 0.2C Rapid charge: 0.5C | |||||||
6 |
Standard charging
| 0.2C CC (constant current) charge to 4.35V, then 4.35V CV(constant voltage) | |||||||
charge till charge current decline to≤ | |||||||||
0.02C | |||||||||
7 |
Discharge Current
| Standard Discharge: 0.2C | |||||||
Max Discharge:0.5C | |||||||||
8 |
Storage temperature
| 1 month: -10~45℃ 6 month : -10~35℃ 20±5 ℃ is recommend long term storage temperature
| |||||||
9 | Weight
| Approx: 12.0g
| |||||||
10 |
Operating temperature
| Charging : 0 ~+45 ℃,≤ 85%RH Discharge:-10~+60 ℃,≤ 85%RH | <0℃Charge shall be prohibited | ||||||
11 | Cell Voltage
| 3.85 ~ 4.05V | As of shipment
| ||||||
3.1 Standard testing environment
Unless specifically stated otherwise, tests must be done within one month of delivery and the number of charging-recharging cycles is fewer than 5. The following is test conditions:
Test conditions:
Ambient Temperature: 23ºC ± 2ºC
Ambient Humidity: 65±20%RH
65±20%RH
NO
| Item
| Test Method
| Criterion
|
1 |
Visual inspection |
visual inspection
| Not allowing any visual defects which will affect the electronic characteristics, such as leakage and damage.
|
2 | Battery Dimension
|
Digital Calipers
| Length:36.5mm Max Width:35.5mm Max Thickness:4.9mm Max |
3 |
Initial Impedance | Internal resistance measured at AC 1KHz after 50-60% charge
|
≤300mΩ |
4 | Rated Capacity 量 | The capacity means the discharge capacity of the cell, which is measured with discharge current of 0.2C with 3.0V cut-off voltage after the standard |
≥530mAh |
charge.
| ||||
5 |
Cycle Life
| Test condition: |
The cycle times is not less than 300
| |
Charge:0.2C to 4.35V | ||||
Discharge:0.2C to 3.0V | ||||
When the discharge capacity reduced to | ||||
70% of rated capacity, Stop testing
| ||||
6 |
High Temperature | A charged battery is placed in an oven |
Discharge 90 percent of the original capacity. | |
for 2 hours at 55ºC±2ºC, then discharged at a 0.2C current to the termination voltage.
| ||||
7 |
Low | A charged battery is placed in a thermal |
Discharge 60 percent of the | |
chamber for 4 hours at -10ºC±2ºC; then | ||||
discharged at 0.2C to the termination | ||||
Temperature | voltage. | original capacity. | ||
8 |
Electricity maintenance | After the standard charging, storied the |
Remaining capacity≥ 85%
| |
cells under the condition as 205 ºC for | ||||
30days, then measured the capacity with 0.2C till 3.0V | ||||
NO
| Item
| Test Method
| Criterion
|
1 |
Constant temperature and constant humidity test
| After Standard Charging, test condition: Temperature:40±2℃ Relative Humidity:90~95%RH Storage Time:48 hours Then return to room temperature for 2 hours,Then 1C discharged to ending voltage
|
No explosion , no fire , no leakage.Dischargeing capacity is not less than 60% original capacity |
2 |
Vibration test
| After Standard Charging, fixed the cell |
No explosion, no fire , no leakage |
to vibration table, then subjected to | |||
vibration test for 30 minutes per axis of | |||
XYZ axes. Frequency rate :1 oct/min | |||
Vibration frequency : 10Hz-30Hz | |||
Excursion(single amplitude): 0.38mm | |||
Vibration frequency : 30Hz-55Hz Excursion(single amplitude): 0.19mm | |||
3 |
Drop Test
| A charged battery is dropped from a |
No explosion, no fire, no leakage. |
height of 1 meter two times onto a concrete surface.
| |||